Tuesday the 18th - copyright Konsorcjum Andziak - HostingFlow.com

106.11

Spray autoclave STERIFLOW - Barriquand

Technical data:

  • Manufacturer - Barriquand, France;
  • Working pressure - 5 bar;
  • Design pressure - 5 bar;
  • Testing pressure (-20ºC) - 10 bar;
  • Working temperature - 135ºC;
  • Design temperature - 150ºC;
  • Heating medium - steam;
  • Capacity - 6.570 dm3;
  • Weight - 2.450 kg;
  • Made in - 1996;
  • Tank made of stainless steel;
  • Inside input - 4 baskets with product;
  • Perfect technical state.


106.10

Screw sterilizer MANZINI with heating space and outer insulation with stainless steel coat

Overall dimensions:

  • length - 5.500 mm;
  • width - 1.150 mm;
  • height - 2.170 mm;

Discharge dimensions:

  • length - 350 mm;
  • width - 150 mm.

Technical data:

  • diameter of screw - 350 mm;
  • screw motor - gearbox;
  • motor power - 1,5 kW/1.440 U/min.;
  • working pressure - up to 4 bar;
  • steamconsumption - up to 500 kg/h;
  • capacity - 3.000 kg/h;
  • pipe and screw made of stainless steel;
  • heating part made of boiler steel;
  • frame made of painted mild steel.

208 3 k

208 3a k

208 3b k

208 3c k


106.9
Horizontal 4-trolleys autoclave - WSA 7 with ful automation of process

Overall dimensions:

  • Length – 4.670 mm;
  • width – 2.016 mm;
  • height – 1.950 mm;

Technical data:

  • capacity of the chamber – 3,41m3 
  • basket capacity – 0,37 m3 
  • number of baskets for one input – 4 szt.;
  • pressure – 0,4 Mpa;
  • temperature - 151 °C;
  • sterilization temperature – up to 132 °C;
  • temperature of water on the exchanger entrance – 10 - 12°C;
  • temperature of steam on the exchanger entrance - 164°C;
  • water pressure – 0,6 MPa;
  • steam pressure - 0,6 Mpa;
  • air pressure for chamber – 0,4 Mpa;
  • air pressure for steering – 0,6 – 0,8 MPa
  • water consumption – about 0,4 m³ / 8h;
  • average steam consumption – 400 kg/h;
  • maximum usage of steam during heating – about 1.500 kg/h;
  • usage of cooling water – about 7 m³/cycle
  • power consumption – 4 kW;
  • heat exchanger type JAD (vertical);
  • weight – 3.923 kg.

Automation characteristic:

  • automatic control of the whole sterilization process (from infeed till discharge of baskets from sterilization tanks);
  • registration of all parameters of seirilization process;
  • visualisation of processes on computer;
  • grafic control panel lets continuous analysis of present process;
  • alarm for all exceeded process parameters;
  • central units of control system with its own memory letting continuous process registration - controllers memory can gather data from over a week of work in case of computer or transsmition line damage;
  • a battery backup system ensuring the operation of controllers, including uninterrupted registration of the process in the event of power failure from the power grid;
  • system adapted to measure the temperature inside the can and calculate the F° parameter.

106 9 k

106 9a k


106.8
Electric-steam autoclave
Overall dimensions:
  • basket diameter - 400 mm
  • height - 600 mm

Technical data:

  • Manufacturer - Spółdzielnia pracy mechaników SMS; Warszawa; Służewiec Przemysłowy; Poland
  • made in 1976
  • maximum working pressure - 2,5 atm
  • power of 3 electric heaters - 9 kW

106 8 k

106 8a k


106.7
Autoclave MLW - 110 l

Total overall dimensins:
  • length - 1.050 mm;
  • width - 560 mm;
  • height with closed lid - 1.240 mm;
  • height with open lid - 1.700 mm.
Basket overall dimensions:
  • diameter - 400 mm;
  • depth - 570 mm.
Technical data:
  • Manufacturer - VEB MLW Medizinische Gerate Berlin, Germany;
  • Machine no. - 25590;
  • Made in 1990;
  • Maximum pressure - 2,45 bar (25 kp/cm²);
  • Maximum temperature - 138°C;
  • Power - 7,5 kW;
  • Power supply - elektryczne 3x380V;
  • Capacity - 110 l.

 
 

The pictures of the machine after reconditioning


106.6

Horizontal autoclave, 2-tank – type WAA 21a

Technical data:

  • Manufacturer – Spomasz Pleszew;
  • Type – WAA 21a;
  • Nr – 104;
  • Tank's weight – 1.341,7 kg;
  • Tank's no. – 30940;
  • Pressure – 0,4 MPa;
  • Temperature – to – 1510C;
  • Tank capacity – 2.790 l;
  • Upper tank – water tank;
  • Lower tank – working tank (pasterization, sterilization);
  • Made in 1991.

The picture of the machine as it is
106.5

Autoclave (pressure kettle) KORIMAT KA 240

Overall dimensions:

  • Depth - 1.210 mm;
  • Width - 900 mm;
  • Height - 1.000 mm;

Technical data:

  • Manufacturer - Christian Wagner, Korimat Metallwarenfabrik GmbH, Germany;
  • Made in - 1995;
  • Autoclave efficiency - 21 kW;
  • Safety valve for up to 100 kW, type SVE 3/4" Intermes TUV.SV.94.946. 3/4" 2,5 bar H 100 2,5;
  • Protection against the overtemperature - contact thermometer switching off the burner at the let temperature;
  • Oil burner - type F8-A Hermann KG  according to DIN 4787;
  • Burner efficiency - 22 kW;
  • Oil pressure up to 1,2 MPa;
  • Oil consumption - ca. 2,5 kg/h;
  • Voltage - 220 V;
  • Working pressure - 2,5 bar;
  • Capacity - 240 l;
  • The highest temperature of incoming water - 50 Celsius degrees;
  • The highest temperature of outgoing water - 120 Celsius degrees;
  • Maximum temperature inside the kettle - 138 Celsius degrees;
  • The lid protected against opening with blokade connected to the release vowel;
  • Weight - 300 kg;
  • Inner diameter of kettle - 680 mm;
  • diameter of oil pipe - 10x1 mm;
  • cylinder sheet metal width - 2 mm;
  • bottom sheet metal width - 4 mm;
  • lid sheet metal width - 3 mm;
  • Used steel - X%CrNi1810 according to DIN 17441.


Water is let from water system at pressure of 0,4 MPa. Autoklave is filled with water up to the certain level (the lid is open). After plunging baskets with cans for serilisation the water level goes up to the upper edghe of the autoclave. After closing the lid and blocking it the pressure is got thanks to the compressed air and the temperature is raised due to oil burner.

The example time of sterilisation of 175 g can (at 1,5 Atm. pressure) - 75 minutes.


 106.4

Basket with trolly for autoclave type WAA 22

Basket's overall dimensions:

  • length - 800 mm;
  • width - 700 mm;
  • height - 700 mm;

Trolly overall dimensions:

  • length - 900 mm;
  • width - 550 mm;
  • height - 300 mm.

Technical data:

  • approx. capacity for 1 l cans - 350 pcs.



106.3
A trolley for an autoclave
WAA 6 i WAA 11

It's used for loading jars and cans that will be pasteurized in an autoclave.

Capacity:
  • cans 1 l - 350 pieces;
  • cans 5 l - 60 pieces;
  • jars 0,5 l - 480 pieces;
  • jars 1 l - 250 pieces.
Weight:
  • net weight - 88 kg;
  • while working - 340 kg

Trolley diagram (for autoclave WAA 6)

106.2
We also offer autoclaves WAA 6 with brand new valves and automation

It's used in food industry for pasteurization and sterilization of fruit, vegetable, meat and fish cans etc.

Overall dimensions:
  • length - 4.200 mm;
  • width - 3.750 mm;
  • height - 2.850 mm.
Technical data:
  • lower 1. and 2. tank capacity - 2 x 2.790 dm3;
  • water dispenser capacity - 2.780 dm3;
  • basket capacity - 370 dm3 ;
  • number of baskets for a single load - 3 pieces;
  • maximum process temperature - 130oC;
  • steam pressure - 0,4 MPa;
  • water pressure - 0,35 MPa;
  • steam demand - 350-400 kg/var;
  • water demand - 3.500 kg/var;
  • weight - 4.500 kg.

Automation characteristic:

  • automatic control of the whole sterilization process (from infeed till discharge of baskets from sterilization tanks);
  • registration of all parameters of seirilization process;
  • visualisation of processes on computer;
  • grafic control panel lets continuous analysis of present process;
  • alarm for all exceeded process parameters;
  • central units of control system with its own memory letting continuous process registration - controllers memory can gather data from over a week of work in case of computer or transsmition line damage;
  • a battery backup system ensuring the operation of controllers, including uninterrupted registration of the process in the event of power failure from the power grid;
  • system adapted to measure the temperature inside the can and calculate the F° parameter.

106.1
Horizontal autoclave WAA 22 with brand new valves and automation

It's used in food industry for pasteurization and sterilization of fruit, vegetable, meat and fish cans etc.

Overall dimensions:
  • length - 4.200 mm;
  • width - 3.750 mm;
  • height - 2.850 mm.
Technical data:
  • lower 1. and 2. tank capacity - 2 x 2.790 dm3;
  • water dispenser capacity - 2.780 dm3;
  • basket capacity - 370 dm3 ;
  • number of baskets for a single load - 3 pieces;
  • maximum process temperature - 130oC;
  • steam pressure - 0,4 MPa;
  • water pressure - 0,35 MPa;
  • steam demand - 350-400 kg/var;
  • water demand - 3.500 kg/var;
  • weight - 4.500 kg.

Automation characteristic:

  • automatic control of the whole sterilization process (from infeed till discharge of baskets from sterilization tanks);
  • registration of all parameters of seirilization process;
  • visualisation of processes on computer;
  • grafic control panel lets continuous analysis of present process;
  • alarm for all exceeded process parameters;
  • central units of control system with its own memory letting continuous process registration - controllers memory can gather data from over a week of work in case of computer or transsmition line damage;
  • a battery backup system ensuring the operation of controllers, including uninterrupted registration of the process in the event of power failure from the power grid;
  • system adapted to measure the temperature inside the can and calculate the F° parameter.



Diagram



Diagram